HELP_VARIABLE
CODE
Code
MATCASING
Casing Material
abs v0
WIDTH
b*h dimensions
75*101 mm
INLETS
Class II - Double insulation
Gland Ø6
IP
IP Degree of Protection
40
ACT
working angle
2 to 4 °
CONTACTS
Microswitch
Contact (1NO+1NC changeover)
APP
Approvals
CE, UL, EAC,
DIR
Reference Directives
LVD - 2014/35/EU
STDR
Reference regulations
TEMP
Operating Temperatures
-25 / +70 °C
TEMPSTOCK
Stock Temperatures
-30 / +80 °C
SHOCK
Protection against electrical shocks
Class II - Double insulation
UI
Rated Insulating Voltage Ui
250 V
GINQ
Pollution Degree
3
UL508
Contact rating secondo UL508
Class II Device
UIMPCONT
Rated impulsive voltage
1 kV
ITH
Conventional thermal current in air free Ith (θ min 40 ° C)
15 A (θ < 40°C)
CTOCTO
Short circuit protection (EU min 500Vac - fuses type gG (gl))
10 A
IEAC
Rated Operational Current Ie - AC-15 (50-60 Hz)
Vac - A
IEDC
Rated Operational Current DC-13
Vdc - A
FREQCOMM
Max. switching frequency
3600 Cicli/h
RESCONT
Resistance Between Contacts
30
TERMN
Connecting Terminals
Screws with washer M3x0,5 (+, -) Philips head
CABLESIN
Connecting Cables Dimensions
0,34 … 1,5 mm²
PROT
Protective Conductor Terminal
/
ELETT
Electrical durability (numer of operations)
100000
MECC
Mechanical durability (Millions of operations)
10