您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
Catalog navigation
所有產品目錄
幾何搜索
草圖搜索
變量搜索
認證的產品目錄
184774
Eaton's CAD
Industrial control, drives, automation and sensors
Control Relays and Timers
23352
Powered by
CAD模型選擇
{eaton_cad/23126/23160/23352/24081.prj},{NB=184774},{PLID=184774},{NETTO_WEIGHT=0.24100},{EF003419=20},{EF008255=0},{EF008256=0},{EF008257=2},{EF000008=45.0},{EF000040=85.6},{EF000049=107.0},{CUSTOMS_TARIFF_NUMBER1=85364900},{PREVIEW=../../../_pool_/26/13/35/24081_preview_20.png},{MANUTYPEDESC=EMR6-R400-A-2},{DESCSHORT=Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
HELP_VARIABLE
PREVIEW
Preview
../../../_pool_/26/13/35/24081_preview_20.png
../../../_pool_/26/13/35/24081_preview_20.png
PLID
184774
184774
MANUTYPEDESC
Manufacturer Type Description
EMR6-R400-A-2
EMR6-R400-A-2
DESCSHORT
Short Description
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ
DESCLONG
Long Description
Insulation monitoring relays, Product range: EMR Measuring and monitoring relays, Status indication via LEDs, Open-circuit principle, Test or reset with button on device or with control input, Configurable fault memory/memory function, Configurable non-volatile fault memory, Wire break detection, Monitoring of: Insulation resistance in non-earthed AC supply systems (three-phase, four-phase systems), insulation resistance in non-earthed DC supply systems (three-phase systems), adjustable sensitivity range: 1 - 100 kΩ, 2 - 200 kΩ, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC , Rated operating voltage for the supply system being monitored: 0 - 400 V AC, 0 - 600 V DC, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 22.5 mm, Standards: IEC/EN 60255-6,
Insulation monitoring relays, Product range: EMR Measuring and monitoring relays, Status indication via LEDs, Open-circuit principle, Test or reset with button on device or with control input, Configurable fault memory/memory function, Configurable non-volatile fault memory, Wire break detection, Monitoring of: Insulation resistance in non-earthed AC supply systems (three-phase, four-phase systems), insulation resistance in non-earthed DC supply systems (three-phase systems), adjustable sensitivity range: 1 - 100 kΩ, 2 - 200 kΩ, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC , Rated operating voltage for the supply system being monitored: 0 - 400 V AC, 0 - 600 V DC, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 22.5 mm, Standards: IEC/EN 60255-6,
INTNO
International product number
4015081788101
4015081788101
NETTO_WEIGHT
Netto weight
0.24100
0.24100
kg
ECLASS_13_0
Insulation-/earth connection monitoring equipment [AKF101019]
ETIM_9_0
Insulation and earth fault monitoring relay [EC001444]
EF003961
Type of electric connection
Screw connection
EF003340
With detachable clamps
false
EF000030
Function
For mixed system
For mixed system
EF003292
External power supply required
false
EF002991
Voltage type (supply voltage)
AC/DC
AC/DC
EF007532
Supply voltage AC 50 Hz
0 - 400
0 - 400
V
EF007533
Supply voltage AC 60 Hz
0 - 400
0 - 400
V
EF007534
Supply voltage DC
0 - 600
0 - 600
V
EF002486
Voltage measuring range
600 - 600
600 - 600
V
EF007024
Rated operating frequency
15 - 60
Hz
EF003419
Line capacity
20
20
µF
EF008202
Response value impedance 1
1 - 100
kO
EF008203
Response value impedance 2
1 - 200
1 - 200
kO
EF003422
Indication of insulation value
false
EF003423
Error registration possible
true
true
EF008255
Number of contacts as normally closed contact
0
EF008256
Number of contacts as normally open contact
0
EF008257
Number of contacts as change-over contact
2
2
EF005294
Voltage type (operating voltage)
AC/DC
AC/DC
EF008206
Operating voltage AC 50 Hz
0 - 400
0 - 400
V
EF008207
Operating voltage AC 60 Hz
0 - 400
0 - 400
V
EF008208
Operating voltage DC
0 - 600
0 - 600
V
EF006706
Rated switch current
4
4
A
EF000008
Width
45.0
45.0
mm
EF000040
Height
85.6
85.6
mm
EF000049
Depth
107.0
107.0
mm
DATA_SHEET
Data sheet
Data sheet
下載CAD模型
生成CAD模型
生成PDF資料表
詢價請求
Previews